[GCB-E100: ALL-IN-ONE 50KW/100KWH C&I BESS]
50kW AC / 100.35kWh nominal (up to 112.53kWh usable). Battery modules + BMS + EMS + HVAC + FSS in single IP54 cabinet (~1200x803x2375mm, ~1300kg). Grade A 280Ah or 314Ah LFP prismatic cells, 6,000+ cycles at 80% DOD. 50kW three-phase 380V inverter. Three modes: Grid-tied / Off-grid / Hybrid. Factory pre-commissioned. CE, RoHS, ISO9001, IEC 62619, UL 1973. 5-year warranty. Configurable to siteGCB-E100 Commercial & Industrial Energy Storage System
A factory-integrated 50kW/100kWh all-in-one BESS cabinet combining battery modules, BMS, EMS, HVAC, and fire suppression system in a single IP54 enclosure. Engineered for peak shaving, solar self-consumption, backup power, TOU arbitrage, and microgrid applications. Every system is configured to site requirements — capacity, operating mode, protection design, and integration interfaces are confirmed per project.
Key Specifications at a Glance
• AC Power: 50kW — Three-Phase 380V AC• Nominal Capacity: 100.35kWh (up to 112.53kWh Usable)• Battery Cells: Grade A LFP — 280Ah / 314Ah Options• Cycle Life: 6,000+ at 25°C, 0.5C, 80% DOD• Architecture: All-in-One — BESS + BMS + EMS + HVAC + FSS• Enclosure: IP54 — ~1200×803×2375mm — ~1300kg• Operating Modes: Grid-Tied / Off-Grid / Hybrid (Configurable)• Cell Certification: IEC 62619 / UL 1973• Certifications: CE / RoHS / ISO9001 / ISO14001• Warranty: 5 Years Standard
PROJECT-FOCUSED ENERGY STORAGE DESIGN
Integrated All-in-One Cabinet:Factory-assembled enclosure combines battery modules, PCS, BMS, EMS, HVAC and fire suppression — reducing on-site coordination, wiring, and commissioning time vs separate-component systems.
Grid & Backup Planning:Choose grid-tied (peak shaving, TOU, demand management), off-grid (islanded backup), or hybrid (solar-plus-storage) mode — configured to your load profile, tariff structure, and utility interconnection rules.
Engineering Before Delivery:Confirm installation space, cable routes, local codes, fire strategy, ambient conditions, and commissioning scope before order. We provides a complete technical proposal within 2–3 business days.
REFERENCE CONFIGURATION & TECHNICAL DATA
The following figures are reference information. Final configuration, compliance documents, and installation conditions are confirmed per project. All parameters configurable to site requirements.
|
System Reference |
Specification |
|
AC Power & Capacity |
50kW / 100.35kWh nominal (up to 112.53kWh usable) — AC-coupled reference configuration. |
|
Battery Cells |
Grade A LFP prismatic cells — 280Ah / 314Ah reference options per project requirement. |
|
Cycle Life |
6,000+ cycles at 25°C, 0.5C charge/discharge, 80% DOD reference conditions. |
|
AC Interface |
50kW three-phase four-wire 380V AC inverter. On-grid, off-grid, and hybrid operation require project validation. |
|
Integrated Subsystems |
BMS (cell-level monitoring), EMS (energy management), HVAC (thermal control), FSS (fire suppression) — all factory-integrated. |
|
Enclosure |
IP54 — approx. 1200×803×2375mm — approx. 1300kg. Verify access, foundation, and lifting before order. |
HOW TO SELECT THE RIGHT C&I ENERGY STORAGE SYSTEM
|
Project Input |
Why It Matters |
|
Load Profile & Tariff |
Defines power, usable energy, and expected value of peak reduction or energy shifting. |
|
Solar & Utility Connection |
Determines AC coupling topology, grid connection conditions, export policy, and operating controls. |
|
Backup Loads & Duration |
Separates essential from non-critical loads for a realistic resilience design. |
|
Site & Compliance Review |
Confirms indoor/outdoor placement, ventilation, clearances, local approvals, and safety requirements. |
PROJECT APPLICATIONS
Factories:Peak shaving, load management, and essential-process backup.
Commercial Buildings:Demand charge reduction for offices, retail, and campuses.
Solar + Storage:Maximize PV self-consumption and dispatch planning.
EV Charging Hubs:Buffer charging peaks and reduce grid upgrade costs.
FREQUENTLY ASKED QUESTIONS:
Q: How should we size a commercial energy storage system?
Start with interval load data (15-minute or hourly), the tariff structure (peak/off-peak rates, demand charges), planned solar capacity, required backup loads, and desired operating objective. The GCB-E100 reference configuration (50kW/100kWh) suits sites with peak demand around 40–60kW and 2–4 hours of storage duration. We validates sizing against your actual load profile and delivers a complete report within 2–3 business days.
Q: Can this system operate with solar and the grid simultaneously?
Yes. The GCB-E100 supports three operating modes: grid-tied (peak shaving, TOU arbitrage with utility-interactive controls), off-grid (islanded backup with seamless transfer), and hybrid (solar-plus-storage with grid-fallback). The applicable mode, protection coordination, and utility interconnection agreement must be confirmed for the actual project and local grid code. All modes are configurable to site — not locked to a single topology.
Q: What customization options are available for the GCB-E100?
The GCB-E100 is fully configurable to project requirements. Customization options subject to project volume include: cell capacity selection (280Ah or 314Ah LFP), AC output power configuration, cabinet color and OEM branding (logo + housing), integration with third-party inverters and EMS platforms, communication protocol (Modbus TCP/RTU, CAN, IEC 61850), and destination-market certification packages. Contact us with your project specification for a customized proposal.
Q: What should be verified before placing an order?
Confirm the final bill of materials, energy capacity, installation location (indoor/outdoor), environmental conditions (ambient temperature, humidity), electrical interface (AC voltage, phase, grid connection), fire-safety clearances per local code, required certificates for the destination market, delivery scope, and commissioning responsibilities. We provides a pre-order verification checklist and remote commissioning support via video call. On-site commissioning engineer available for projects above 500 kWh.